Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters

Database
Main subject
Language
Document Type
Year range
1.
medrxiv; 2022.
Preprint in English | medRxiv | ID: ppzbmed-10.1101.2022.03.24.22272891

ABSTRACT

BackgroundPerformances of rapid antigen diagnostic tests (Ag-RDTs) with nasal self-sampling, and oropharyngeal plus nasal (OP-N) self-sampling, in the Omicron period are unknown. MethodsProspective diagnostic accuracy study among 6,497 symptomatic individuals aged >16 years presenting for SARS-CoV-2 testing at three test-sites. Participants were sampled for RT-PCR (reference test) and received one Ag-RDT to perform unsupervised with either nasal self-sampling (during the emergence of Omicron, and after Omicron share was >90%, phase-1) or with OP-N self-sampling (in a subsequent phase-2; Omicron share >99%). The evaluated tests were Acon Flowflex (Flowflex; phase-1 only), MP Biomedicals (MPBio), and Siemens-Healthineers Clinitest (Clinitest). FindingsDuring phase-1, 45% of Flowflex, 29% of MPBio, and 35% of Clinitest participants were confirmatory testers (previously tested positive by a self-test at own initiative). Overall sensitivities with nasal self-sampling were 79.0% (95% CI: 74.7-82.8%) for Flowflex, 69.9% (65.1-74.4%) for MPBio, and 70.2% (65.6-74.5%) for Clinitest. Sensitivities were substantially higher in confirmatory testers (93.6%, 83.6%, and 85.7%, respectively) than in those who tested for other reasons (52.4%, 51.5%, and 49.5%, respectively). Sensitivities decreased by 6.1 (p=0.16 by Chi-square test), 7.0 (p=0.60), and 12.8 (p=0.025) percentage points, respectively, when transitioning from 29% to >95% Omicron. During phase-2, 53% of MPBio, and 44% of Clinitest participants were confirmatory testers. Overall sensitivities with OP-N self-sampling were 83.0% (78.8%-86.7%) for MPBio and 77.3% (72.9%-81.2%) for Clinitest. Comparing OP-N to nasal sampling, sensitivities were slightly higher in confirmatory testers (87.4% and 86.1%, respectively), and substantially higher in those testing for other reasons (69.3% and 59.9%, respectively). InterpretatioSensitivities of three Ag-RDTs with nasal self-sampling decreased during Omicron emergence but was only statistically significant for Clinitest. Sensitivities were substantially influenced by the proportion of confirmatory testers. Addition of oropharyngeal to nasal self-sampling improved sensitivities of MPBio and Clinitest. FundingDutch Ministry of Health, Welfare, and Sport. Research into contextO_ST_ABSEvidence before this studyC_ST_ABSSARS-CoV-2 rapid antigen diagnostic tests (Ag-RDTs) require no or minimal equipment, provide a result within 15-30 minutes, and can be used in a range of settings including for self-testing at home. Self-testing may potentially lower the threshold to testing and allows individuals to obtain a test result quickly and at their own convenience, which could support the early detection of infectious cases and reduce community transmission. Real world evidence on the performance of unsupervised nasal and oropharyngeal plus nasal (OP-N) self-sampling in the Omicron variant period is needed to accurately inform end-users and policymakers. Therefore, we conducted a large prospective diagnostic accuracy study of three commercially available Ag-RDTs with self-sampling (the Acon Flowflex test, the MP Biomedicals test, and the Siemens-Healthineers Clinitest) during and after the emergence of Omicron using RT-PCR as the reference standard. Our aims were to evaluate whether the accuracies of Ag-RDTs with nasal self-sampling changed over time with the emergence of Omicron; and to determine whether addition of oropharyngeal to nasal self-sampling with the same swab yielded higher diagnostic accuracies. What this study addsThe large comprehensive study was conducted in almost 6,500 participants with symptoms when presenting for routine SARS-CoV-2 testing at three public health service COVID-19 test-sites in the Netherlands. During the study, conducted between 21 December 2021 and 10 February 2022, the percentage of the Omicron variant in samples from the national SARS-CoV-2 pathogen surveillance increased from 29% in the first week to 99% in the last week of the study. The period during which the Omicron variant was dominant was divided into a nasal sampling phase (phase-1; Omicron present in >90% of surveillance samples) and an OP-N sampling phase (phase-2; Omicron share was >99%). In phase-1, 45% of Flowflex, 29% of MPBio, and 35% of Clinitest participants visited the test-site because of a positive self-test (confirmatory testers). Overall sensitivities with nasal self-sampling were 79.0% (95% CI: 74.7-82.8%) for the Flowflex, 69.9% (65.1-74.4%) for the MPBio, and 70.2% (65.6-74.5%) for the Clinitest Ag-RDT. Sensitivities were 94%, 84%, and 86%, respectively, for confirmatory testers, and 52%, 52%, and 50%, respectively, for those who had other reasons for getting tested. Sensitivities were 87.0% (79.7-92.4%), 83.1% (72.9-90.7%), and 80.0% (51.9-95.7%), respectively, in the first week, and decreased by 6.1 (p=0.16 by Chi-square test), 7.0 (p=0.60), and 12.8 (p=0.025) percentage points in the final week of the study. In Phase-2, 53% of MPBio and 44% of Clinitest participants were confirmatory testers. Overall sensitivities with OP-N self-sampling were 83.0% (78.8%-86.7%) for MPBio and 77.3% (72.9%-81.2%) for Clinitest. When comparing OP-N to nasal sampling, sensitivities were slightly higher in confirmatory testers (87.4% and 86.1%, respectively), and substantially higher in those testing for other reasons (69.3% and 59.9%). Implications of all the available evidenceThe sensitivities of three commercially available Ag-RDTs performed with nasal self-sampling decreased during the emergence of Omicron, but this trend was only statistically significant for Clinitest. Addition of oropharyngeal to nasal self-sampling improved the sensitivity of the MPBio and Clinitest, most notably in individuals who visited the test-site for other reasons than to confirm a positive self-test. Based on these findings, the manufacturers of MPBio and Clinitest may consider extending their instructions for use to include combined oropharyngeal and nasal sampling, and other manufacturers may consider evaluating this as well.


Subject(s)
COVID-19
2.
medrxiv; 2022.
Preprint in English | medRxiv | ID: ppzbmed-10.1101.2022.01.28.22269783

ABSTRACT

Introduction: Rapid antigen detection tests (RDT) are suitable for large-scale testing for SARS-CoV-2 among the population and recent studies have shown that self-testing with RDT in the general population is feasible and yields acceptable sensitivities with high specificity. We aimed to determine the accuracy of two different RDT, with two different sample collection methods for one of the RDT among healthcare workers (HCW). Secondary objectives were to determine the accuracy of RDT using a viral load cut-off as proxy of infectiousness and to identify predictors for a false negative RDT. Methods: Centers that participated were secondary care hospitals, academic teaching hospitals, and long-term care facilities. All HCW that met inclusion criteria were asked to perform a RDT self-test next to a regular SARS-CoV-2 nucleic acid amplification test (NAAT). Three study groups were created. Study group 1; Veritor System, Becton Dickinson, Franklin Lakes, USA (BD-RDT) with combined oropharyngeal - mid-turbinate nasal sampling, group 2; BD-RDT with mid-turbinate nasal sampling only and group 3; SD Biosensor SARS-CoV-2 Rapid Antigen Test, Roche, Basel, Switzerland (Roche-RDT) with combined oropharyngeal - mid-turbinate nasal sampling. RDT accuracy was calculated using NAAT as reference standard. For samples processed in the cobas(R) 6800/8800 platform (Roche Diagnostics, Basel, Switzerland), established cycle threshold values (Ct-values) could be converted into viral loads. A viral load cut-off of [≥]5.2 log10 SARS-CoV-2 E gene copies/ml was used as proxy of infectiousness. Logistic regression analysis was performed to identify predictors for a false negative RDT. Results: In total, 7,196 HCW were included. Calculated sensitivities were 61.5% (95%CI 56.6%-66.3%), 50.3% (95%CI 42.8%-57.7%) and 74.2% (95%CI 66.4%-80.9%) for study groups 1, 2 and 3, respectively. After application of a viral load cut-off as a proxy for infectiousness for samples processed in the cobas(R) 6800/8800 platform sensitivities increased to 82.2% (95%CI 76.6-86.9%), 61.9% (95%CI 48.8%-73.9%) and 90.2% (95%CI 76.9%-97.3%) for group 1, group 2 and group 3, respectively. Multivariable regression analysis showed that use of Roche-RDT (p <0.01), combined oropharyngeal - mid-turbinate nasal sampling (p <0.05) and the presence of COVID-19 like symptoms at the time of testing (p <0.01) significantly reduced the likeliness of a false-negative RDT result. Conclusion: SARS-CoV-2 RDT has proven able to identify infectious individuals, especially when upper respiratory specimen is collected through combined oropharyngeal - mid-turbinate sampling. Reliability of self-testing with RDT among HCW seems to depend on the type of RDT, the sampling method and the presence of COVID-19 like symptoms at the time of testing.


Subject(s)
COVID-19
3.
medrxiv; 2021.
Preprint in English | medRxiv | ID: ppzbmed-10.1101.2021.02.21.21252153

ABSTRACT

IntroductionSelf-testing for COVID-19 infection with lateral flow assay SARS-CoV-2 rapid antigen detection tests (RDT), provides rapid results and could enable frequent and extensive testing in the community, thereby improving the control of SARS-CoV-2. The objective of this study is to evaluate the performance of self-testing using RDT without assistance. MethodsParticipants visiting a municipal SARS-CoV-2 testing centre, received self-testing kits containing either the BD Veritor System (BD RDT) or Roche SARS-CoV-2 antigen detection test (Roche RDT). Oro-nasopharyngeal swabs were collected from the participants for qRT-PCR testing. As a proxy for contagiousness, viral culture was performed on a selection of qRT-PCR positive samples to determine the Ct-value at which the chance of a positive culture was dropping below 0.5 (Ct-value cut-off). Sensitivity and specificity of self-testing were compared to qRT-PCR with a Ct-value below the Ct value cut-off. Determinants independently associated with a false-negative self-test result were determined. ResultsA total of 3,215 participants were included (BD RDT n=1604; Roche RDT n=1611). Sensitivity and specificity of self-testing compared to the qRT-PCR results with Ct-value below the Ct-value cut-off was 78.0% (95% CI:72.5-82.8) and 99.4% (95%CI: 99.0-99.6) respectively. Determinants independently associated with a false-negative self-testing results were: higher age, low viral load and finding self-testing difficult. DiscussionSelf-testing using currently available RDTs has a high specificity and relatively high sensitivity to identify individuals with a high probability of contagiousness. The performance of two tests were comparable. This application has the potential for frequent and extensive testing which may be an aid to lift restrictions to society while controlling the spread of SARS-CoV-2.


Subject(s)
COVID-19
SELECTION OF CITATIONS
SEARCH DETAIL